Communications
6. Communications
Communication lines are used to upload and download
information between the access control panel and the
VeriTrax AS-225 software. When the access control panel and
the computer are communicating,
the system’s two LEDs flash
accordingly.
The RX LED flashes when the controller receives data
The TX LED flashes when the controller transmits data
Note:
The access control panel address is defined in the
VeriTrax AS-225 software.
It is important that the DIP switch and the software are set
to the same address.
There are three connection modes:
Serial Network (RS-232 or RS-485)
Modem Network
TCP/IP Network
6.1 Serial Network Connection
The computer serial port controlling the access control panel is
set from within the VeriTrax AS-225 software. The default is
9600bps for direct connection to the computer.
When using an RS-232 connector, only one access control
panel can be linked to each communication port on the
computer. Use an RS-485 if you wish to connect more than
one panel on one communication port.
Note:
The J1 switch must be in the correct position to select the
RS-232 communication.