Programming
AC-F/G4x Family Installation and Programming Manual 43
5.11.4 Standard Method for Codes Enrolling
To enroll codes using the Standard method:
1. Enter Programming mode.
2. Press 7 to enter Menu 7.
The Door indicator turns orange.
3. Enter the 3-digit user slot number into the
memory (from 001 to 500) so as to enroll a
primary or secondary code. For example, the
user slot 003 represents User No. 3.
4. There are three possibilities:
If the selected slot has no primary code,
the Mode indicator flashes green,
indicating that the controller is ready to
accept a primary code
If the selected slot already has a primary
code, but no secondary code, the Mode
indicator flashes red, indicating that the
controller is ready to accept a secondary
code.
If the selected slot already has a primary and secondary code,
a long beep is heard and the controller returns to Normal
mode.