Programming
AC-F/G4x Family Installation and Programming Manual 39
5.8.2.9 Auxiliary Mode 8
Auxiliary input function: Green LED control
Auxiliary output activated by: Valid user code, Auxiliary code
For example, in Auxiliary Mode 8, the controller can function as a
two-door controller and also provide indicator functionality control.
The auxiliary relay is connected to the lock on the second door. The
auxiliary setting defines the Door Open time for the second door. The
auxiliary input is used to control the Door indicator. If the auxiliary
input is open, the indicator flashes green; if the auxiliary input is
closed, the Door indicator flashes red.
This mode takes control of the Door indicator LED.
The indicator LED is not lit when:
A valid code is entered
While in Secure mode, when waiting for a secondary code
5.8.2.10 Auxiliary Mode 9
Auxiliary input function: Red LED control
Auxiliary output activated by: Valid user code, Auxiliary code
For example, in Auxiliary Mode 9, the controller can function as a
two-door controller and also provide indicator functionality control.
The auxiliary relay is connected to the lock on the second door. The
auxiliary setting defines the Door Open time for the second door. The
auxiliary input is used to control the indicator. If the auxiliary input is
open, the Door indicator flashes red; if the auxiliary input is closed,
the Door indicator flashes green.
This mode takes control of the Door indicator LED.
The indicator LED is not lit when:
A valid code is entered
While in Secure mode, when waiting for a secondary code
Vista de página 38