Fel! Formatmallen är inte definierad.
AS-215 PC management software
Page 19
Door Property Tab
This dialog box has the following fields:
Field Sub-field Description
Description
Type in the relevant description for the door
Auto relock
This field has the following options indicating when the
door automatically locks:
None: Lock strike opens for programmed period of time
On door close: Lock strike stops when the door is closed
On door open: Lock strike stops when the door is opened
First person
delay for
unlock
Indicating that automatic unlocked starts after first user
access. This is only available after this checkbox is
checked
Automatic
unlock
Select the relevant time zone
Door lock
Output 1
Interlock with
Door 1 / Door 2
At Double Door Controller: Indicating that the door can
be opened only if the second door is closed
Door open time
This field defines the amount of time that the door is
opened after valid access
Extended door
open time
This option is for users that have cards with special access
permission. For example for delivering goods.
Timers
Timer- Siren
This field defines that a siren type alarm is sounded.
True for Readers Tamper and Single Door Tamper
3. Double click on the reader. The reader dialog box opens.