Programming
AC-F4x and AC-G4x Family Manual
Page 25
Note:
Auxiliary code does not function in secure mode.
Auxiliary code only works when the auxiliary mode is 0, 1, 8 or 9.
Wrong entries: you will hear a long beep and the controller will
return to its normal mode.
Code 0000 will erase and deactivate the auxiliary code.
1) Enter the programming mode.
2) Depress 2 to enter Menu 2.
The Mode indicator will turn orange.
3) Enter a new auxiliary code.
4) System returns to its normal mode.
You will hear three beeps.
The Door indicator will turn off.
The Mode indicator will turn green.
4.4 CHANGING THE PROGRAMMING CODE
Note:
The code 0000 is not valid; thus, the programming code cannot
be erased.
Wrong entries: you will hear a long beep and the controller will
return to its normal mode.
1) Enter the programming mode.
2) Depress 3 to enter Menu 3.
The Mode indicator will turn green.
3) Enter the new programming code.
4) System returns to its normal mode.
You will hear three beeps.
The Door indicator will turn off.
The Mode indicator will turn green.