Programming the AC-B/C/D3x
AC-B/C/D3x Family Installation and Programming Manual 33
10.9.4 Enrolling Primary and Secondary Codes Using
the Standard Method
To enroll primary and secondary codes using the Standard
method:
1. Enter Programming mode.
2. Press 7 to enter Menu 7.
The Mode LED turns orange.
3. Perform one of the following:
a. Enter a 3-digit User Slot number
between 001 and 500 to indicate
the user to whom you want to
enroll a Primary or Secondary code.
For example, the User Slot 003
represents User #3.
If the selected slot has no Primary
Code, the Mode LED flashes green,
indicating that the controller is
ready to accept a Primary Code.
If the selected slot already has a
Primary Code but no Secondary
code, the Mode LED flashes red,
indicating that the controller is
ready to accept a Secondary Code.
If the selected slot already has a Primary and Secondary Code,
you hear a long beep and the controller returns to Normal
mode.
b. Present a proximity card (AC-x32 models) or enter the 4-digit
PIN that you want to assign as the Primary or Secondary Code
for this slot number.